Construction of corrugated iron carports

21 August 2025

REQUEST FOR QUOTATION

 

Quotations are hereby invited from CIDB registered contractor for Construction of corrugated iron carports at Thabazimbi Campus


Advert: WTC- THAB/CCC/08/2025- Construction of corrugated iron carports at Thabazimbi Campus

Quotations displaying quotation number WTC- THAB/CCC/08/2025 must be submitted on/or before the closing time.

Closing date                               : 09/09/2025

Closing time                              : 14H00 pm

Validity Period of Tender          : 90 days

 

Compulsory site meeting: 29/08/2025 at 11:00 at the following physical address:

Waterberg TVET College

Thabazimbi Campus

Extension 5& 8

Regorogile

Thabazimbi

 

All enquiries related to this RFQ may be addressed to this email: scm@waterbergcollege.co.za

NB: This email is for enquiries only, please submit your quotation on the below email         

The following documents must accompany your quotation:

·       Copy of CK certificate must be attached indicating member’s names and percentage ownership within the enterprise,

·       Valid tax compliant letter with PIN

·       BBBEE registration/a sworn affidavit to claim Preferential Points

·       Proof of CSD registration Report

·       Print screen of CIDB registration of 2GB or higher

·       Proof of previous experience (Contactable reference) for construction of carports (Attach a minimum of two reference letters)


Waterberg TVET College promotes fair competition among suppliers. Any form of bid-rigging or collusive bidding will be unacceptable. Bidders will be disqualified.

Contractors must submit their quotations and all attachments to Waterberg TVET College Central office at Cnr Hooge & Totius streets, Chroompark, 0600 or can alternatively be sent by email to: rfq@waterbergcollege.co.za

Waterberg TVET College does not bind itself to accept the lowest or any quotation. The right is reserved to accept any tender in whole or in part and re-advertise this quotation any time after the closing date.


SCOPE OF WORK

Concrete footing for steel structure:

350mm by 350mm by 600mm depth footing

20 MPa concrete footing for steel structure

250x250x2mm steel plate welded on the bottom of 100mm square tube column, to act as a punching shear stud

Structure height from ground level-2,45m-Front

Structure height from ground level-2,40m back

 

Column to roof detail:

100x100x3mm steel square tube to carry the roof weight of the structure

115x50x3mm thick rectangular steel lip channel tube with 150mm overhang

50x50x2mm square tube for truss

Chromadek IBR roof sheeting-dove grey fixed to 50x50x2mm square tubes truss with steel tek screws and washers

 

Finishes

1 layer of primer paint for all steel tubes

2 layers of high gloss enamel paint (dove grey) for all steel tubes

 

Double volume parking bay