21 August 2025
REQUEST
FOR QUOTATION
Quotations are hereby invited from CIDB registered contractor for Construction of corrugated iron carports at Thabazimbi Campus
Advert: WTC- THAB/CCC/08/2025- Construction of corrugated iron carports at Thabazimbi Campus
Quotations displaying quotation number WTC- THAB/CCC/08/2025 must be submitted on/or before the closing time.
Closing
date : 09/09/2025
Closing
time : 14H00 pm
Validity
Period of Tender : 90 days
Compulsory site meeting: 29/08/2025 at 11:00 at the following physical address:
Waterberg
TVET College
Thabazimbi
Campus
Extension
5& 8
Regorogile
Thabazimbi
All
enquiries related to this RFQ may be addressed to this email: scm@waterbergcollege.co.za
NB: This email is for enquiries only, please submit your quotation on the below email
The following documents must accompany your quotation:
· Copy of
CK certificate must be attached
indicating member’s names and percentage ownership within the enterprise,
· Valid tax compliant letter with PIN
· BBBEE registration/a sworn affidavit to
claim Preferential Points
· Proof of CSD registration Report
· Print screen of CIDB registration of 2GB
or higher
· Proof of previous experience (Contactable reference) for construction of carports (Attach a minimum of two reference letters)
Waterberg TVET College promotes fair competition among suppliers. Any form of bid-rigging or collusive bidding will be unacceptable. Bidders will be disqualified.
Contractors must submit their quotations and all attachments to Waterberg TVET College Central office at Cnr Hooge & Totius streets, Chroompark, 0600 or can alternatively be sent by email to: rfq@waterbergcollege.co.za
Waterberg
TVET College does not bind itself to accept the lowest or any quotation. The
right is reserved to accept any tender in whole or in part and re-advertise
this quotation any time after the closing date.
SCOPE OF WORK
Concrete footing for steel structure: 350mm by 350mm by 600mm depth footing 20 MPa concrete footing for steel structure 250x250x2mm steel plate welded on the bottom
of 100mm square tube column, to act as a punching shear stud Structure height from ground
level-2,45m-Front Structure height from ground level-2,40m
back
Column to roof detail: 100x100x3mm steel square tube to carry the
roof weight of the structure 115x50x3mm thick rectangular steel lip
channel tube with 150mm overhang 50x50x2mm square tube for truss Chromadek IBR roof sheeting-dove grey fixed
to 50x50x2mm square tubes truss with steel tek screws and washers
Finishes 1 layer of primer paint for all steel tubes 2 layers of high gloss enamel paint (dove
grey) for all steel tubes
Double volume parking bay
|